![]() ![]() 1 SERVICE MANUAL E SIGMA CONTROL Index: BUB 07 GL-No.: BA V4 Publisher: KAESER KOMPRESSOREN GmbH Coburg : PO Box 2143 : GERMANY : Tel (0) : Fax (0)ģ Table of Contents Chap ter - Pag e 1 Technical specification Power Supply Sensors Hardware Interface pin connections RS RS Profibus Software Safety Regulations Explanation of Symbols and Instructions General Instructions Safety Regulations for the Controller General Short Description Finding the best Type of Pressure Regulation DUAL Control QUADRO Control VARIO Control Mode Operation Control Panel The SIGMA CONTROL System EMERGENCY STOP Pushbutton Function keys Key functions Light emitting diodes and plain text display LED functions Display Switching the Compressor Package On and Off Switching on locally Switching off locally Switching on and off in remote Switching on and off with the clock Resetting Alarm Messages Acknowledgement of Warning Messages Alarm and Warning Messages Frequently Programmed Functions Procedure for initial startup (Standard Mode) Procedure for initial startup (Expert Mode) Correcting the package pressure Carrying out maintenance The compressor package is to be operated with a base load sequencer MAC 41 as an example iĤ Table of Contents Chap ter - Pag e MVS 8000 as an example VESIS as an example Two rotary screw compressors in sequence Base load sequencing of two compressor packages with Sigma Control via the RS 485 interface Settings on both SIGMA CONTROLs Settings on the master SIGMA CONTROL Settings on the slave Sigma Control Settings on both SIGMA CONTROLs Sequencing SIGMA and pressure switch controlled compressors Sigma Control Menus Main Menu Password Protection Display and Setup Level Display Level Display Level in SIGMA Control Status Data Messages Statistics Print Printer clock Analog data Operating data Maintenance Setting/resetting the maintenance interval counter Display and Setup Level Password Enter password Clock General description of the clock The daily schedule The weekly schedule The yearly schedule Clock key: Configuration General Pressure settings Compressor configuration System pressure Vacuum package System pressure of the vacuum package Load control Control mode DUAL Control settings (normal control) iiĥ Table of Contents Chap ter - Pag e QUADRO control settings Modulating control Acknowledgement (reset) Compressor start I/O periphery timer Components Motor Power switching Oil circulation Oil separator Booster Air main charging Package discharge temperature Package Test Compressor test TÜV check Pressure relief valve Temperature sensor / shutdown temperature Binary input/output check Lamps test Communication RS 232 interface RS 485 interface L2DP bus (Profibus) SMS Saving settings Languages Setting the language iiiĦ Table of Contents Chap ter - Pag e ivħ Technical Specification 1 Technical specification 1.1 Power Supply Power supply for SIGMA CONTROL Rated voltage V DC (stabilized) Consumption A (standard controller) Consumption A (with expander board) Auxiliary voltage for sensors (from the controller) Voltage V DC Note All voltages are generated within the compressor package itself 1.2 Sensors Pressure transducer: Output signal. ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |